Go Direct® Chloride Ion-Selective Electrode
The Go Direct Chloride Ion-Selective Electrode (ISE) is used to measure the concentration of chloride (Cl–) in aqueous samples. It connects via Bluetooth® wireless technology or via USB to your device.
$462.00
Education Levels
Product Families
The concentration of chloride gives a quick measurement of the salinity of water samples. Use the Go Direct Chloride Ion-Selective Electrode to wirelessly measure chloride levels in ocean saltwater or salt in food samples.
The versatile BNC connector allows students to easily replace the electrode when it expires or becomes damaged. You need only replace the electrode and not the entire sensor—lowering your overall equipment costs.
The Go Direct Chloride Ion-Selective Electrode has a combination-style, non-refillable, gel-filled electrode. Unlike other ISEs available from Vernier, the Go Direct Chloride Ion-Selective Electrode has a solid-state membrane that does not need to be replaced.
Rechargeable Battery—Ready When You Are
The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our free Graphical Analysis™ 4 app or LabQuest 3 App. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.
Wired or Wireless—The Flexibility to Choose
Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our free Graphical Analysis™ 4 app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your classroom or laboratory.
Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.
Range (mV): ±1000 mV
Range (concentration): 2 to 35,000 mg/L (or ppm)
Accuracy: ±10% of full scale (calibrated 10 to 1000 mg/L)
Interfering ions: CN–, Br–, I–, S2-, OH–, NH3
pH range: 2–12 (no pH compensation)
Temperature range: 0–80°C (no temperature compensation)
Electrode slope: 56 ±3 mV/decade at 25°C
Electrode resistance: 1 to 5 MΩ
Minimum sample size: must be submerged 2.8 cm (1.1 in)
Connections:Wireless: Bluetooth
Wired: USB
Go Direct ISE Amplifier attached to a Go Direct Chloride Ion-Selective Electrode BNC
Micro USB cable
30 mL bottle of High Standard solution with SDS (1000 mg/L Cl–)
30 mL bottle of Low Standard solution with SDS (10 mg/L Cl–)
Polishing strips
Short-Term ISE Soaking Bottle
Go Direct® Ammonium Ion-Selective Electrode BNC (GDX-NH4-BNC)
Go Direct® Calcium Ion-Selective Electrode BNC (GDX-CA-BNC)
Go Direct® Charge Station (GDX-CRG)
Go Direct® Nitrate Ion-Selective Electrode BNC (GDX-NO3-BNC)
Go Direct® Potassium Ion-Selective Electrode BNC (GDX-K-BNC)
Go Direct® Sensor Clamp (GDX-CLAMP)
Go Direct® 300 mAh Replacement Battery (GDX-BAT-300)
Go Direct® Ion-Selective Electrode Amplifier (GDX-ISEA)
Micro USB Cable (CB-USB-MICRO)
Electrode Storage Bottles (BTL-ES)
Go Direct® Chloride Ion-Selective Electrode BNC (GDX-CL-BNC)
Standard Cl ISE Solution ()
User Manual: https://www.vernier.com/manuals/gdx-cl/
Warranty: 5-year limited warranty (1 year on battery, consumables excluded)
FAQ: https://www.vernier.com/til/4350/